Amran

Showing all 6 results

  • Amran

    Amran 600V Low Voltage (LV) Ground Fault Current Transformers (CTs)

    Amran 600V Low Voltage (LV) Ground Fault Current Transformers (CTs) are used to detect ground fault currents in switchgears, metering panels, and control panels. These ground fault CTs are available with large window sizes in rectangle or round shapes, and have three different encapsulation choices. Each product is tested for all routine tests specified by the standards. Amran Instrument Transformers are tested 100% at final stage before shipping. Final tests are carried out per IEEE C57.13 or IEC 60044, or relevant test standards, and all records are traceable by serial and batch numbers.

  • Amran

    Amran 600V Low Voltage (LV) Single or Three Phase Potential Transformers (PTs), Voltage Transformers (VTs)

    Amran 600V Low Voltage (LV) Potential Transformers (PTs), or voltage transformers (VTs), are available in single phase or three phase designs. These low voltage PTs are offered in many different sizes with or without mounting brackets, and are available with single and multi secondary options. Each product is tested for all routine tests specified by the standards. Amran Instrument Transformers are tested 100% at final stage before shipping. Final tests are carried out per IEEE C57.13 or IEC 60044, or relevant test standards, and all records are traceable by serial and batch numbers.

  • Amran

    Amran 600V Low Voltage (LV) Split Core Current Transformers (CTs)

    Amran 600V Low Voltage (LV) Split Core Current Transformers (CTs) are used in metering, and energy management applications. They are easily installed on long primary conductors, and voltage output is possible with a built in resistor. These split core CTs are available in standard or custom solutions with various construction options, a wide selection of windows and sizes, and many ratios starting from 50:5A.

  • Amran

    Amran 600V Low Voltage (LV) Switchgear, General Purpose Current Transformers (CTs)

    Amran 600V Low Voltage (LV) Switchgear and General Purpose Current Transformers (CTs) are designed and developed for OEM specific equipment. These CTs can be supplied with or without a secondary resistor, and are available in accuracy classes to meet application needs. Amran offers these current transformers in may different sizes, and with vaious construction options to meet your project specifications. Each product is tested for all routine tests specified by the standards. Amran Instrument Transformers are tested 100% at final stage before shipping. Final tests are carried out per IEEE C57.13 or IEC 60044, or relevant test standards, and all records are traceable by serial and batch numbers.

  • Amran

    Amran Medium Voltage (MV) Single Phase Potential Transformers (PTs), Voltage Transformers (VTs)

    Amran Medium Voltage (MV) Single Phase Potential Transformers are available in either single bushing or two bushing designs. These potential transformers (PTs), or voltage transformers (VTs), are easy to install, and are available in a wide ranges of sizes, with or without mounting brackets. Each product is tested for all routine tests specified by the standards. Amran Instrument Transformers are tested 100% at final stage before shipping. Final tests are carried out per IEEE C57.13 or IEC 60044, or relevant test standards, and all records are traceable by serial and batch numbers.

  • Amran

    Amran Medium Voltage (MV) Switchgear Current Transformers (CTs)

    Amran Medium Voltage (MV) Switchgear Current Transformers (CTs) are specifically designed to mount in medium voltage switchgears, usually 5, 15, 27, and 38kV switchgears. The CTs are normally mounted over primary bushings in MV switchgears, and they have integrated corner mounting holes for easy installation. These Amran MV switchgear CTs meet IEEE/ANSI C57.13, or IEC 61819-1 accuracy classes for metering and/or relaying. A wide range of windows, sizes and ratios are available.